Description

Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to inorganic ACFoam®-III coated glass facers. Available in 0.625” thick 4ft x 8ft (1220mm x 2440mm) and 0.625” thick 4ft x 4ft (1220mm x 1220mm) panels. Manufactured in accordance with ASTM C1289, Type II, Class 4, Grade 1 (80 psi (551 kPa) minimum, up to 110 psi (758 kPa) compressive strength).

THICKNESS THERMAL PCS/PKG
in mm 3R-VALUE 4RSI
0.625 15.9 2.5 0.44 36

3 Determined by ASTM test method C518 at 75°F mean temperature.
4 RSI is the metric expression of R-value (m2•K/W).

THICKNESS FM RATING FIELD FASTENERS PER 4’x8’ BOARD
0.625″ 1-75 12
1-90 16

Tested ratings refer to selected adhered membranes.

Manufactured and tested for use in new and re-roofing applications. ACFoam-HD CoverBoard-FR is used in mechanically attached single-ply, fully adhered single-ply and self-adhered “peel & stick” roofing systems. These roofing systems depend on proper installation for successful performance. Refer to FM Approvals® RoofNav and UL Online Certifications Directory for additional application details and approvals.

PROPERTY TEST METHOD RESULTS
DIMENSIONAL STABILITY ASTM D2126

T < 4.0%, L & W < 1.0%

COMPRESSIVE STRENGTH ASTM D1621 2 Grade 1
WATER ABSORPTION ASTM C209 < 4.0%
WATER VAPOR TRANSMISSION ASTM E96 < 1.5 perm (85.0ng/(Pa•s•m2))
FLAME SPREAD ASTM E84 (10 min.)

<75

SMOKE DEVELOPMENT ASTM E84 (10 min.)

<450

TENSILE STRENGTH ASTM D1623 > 2000 psf (95 kPa)
SERVICE TEMPERATURE -100°F to +250°F

1 Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of ≤75 and smoke development ≤450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic insulation when used in FM 4450 or UL 1256. Physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation.
2 80 psi (551 kPa) minimum, up to 110 psi (758 kPa)

  • ASTM C1289, Type II, Class 4, Grade 1
  • FM Standard 4450/4470 Approved Refer to FM Approvals® RoofNav for Specific System Details
  • UL Standard 790 (ASTM E108) Roofing Systems Classification
  • UL Class A Over Combustible Decks with UL Classified EPDM, PVC and TPO Membranes
  • IBC Chapter 26 & NBC Sections on Foam Insulation